Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Type of study
Language
Year range
1.
Acta cir. bras ; 27(7): 454-459, jul. 2012. ilus, graf, tab
Article in English | LILACS | ID: lil-640092

ABSTRACT

PURPOSE: To study the intraperitoneal use of polyester with collagen and polytetrafluoroethylene meshes in the correction of total ventral wall defects in rats. METHODS: Thirty two rats were evaluated and divided randomly into four groups and underwent laparotomy and preparation of total defects of the abdominal wall. Next, the correction of the defect with the intraperitoneal placement of the chosen mesh was performed. The rats were submitted to euthanasia at 30 and 90 days after surgery. Were analyzed the macroscopic adhesions and microscopic aspects, and applied stress rupture test RESULTS: All animals showed intraperitoneal adhesions in varying degrees, with no statistical significance difference. There was no difference also between groups in the evaluation of stress rupture tests. On the microscopic aspect, the A30 group had less inflammatory reaction and less formation of granulomas and foreign body reaction that the B30 group, with significant difference. CONCLUSIONS: There was no difference in intraperitoneal adhesion and tensile rupture strength among groups. Group B30 presented granulomatous inflammatory reaction at the site of mesh attachment to the wall significantly higher than the A30.


OBJETIVO: Estudar comparativamente o uso intraperitoneal das telas de poliéster com colágeno e politetrafluoretileno na correção de defeitos totais da parede ventral em ratos. MÉTODOS: Foram avaliados 32 ratos distribuídos em quatro grupos aleatórios e submetidos à laparotomia e confecção de defeitos totais da parede abdominal. Em seguida, foi realizada a correção do defeito com a colocação intraperitoneal das telas. A eutanásia ocorreu aos 30 e 90 dias do pós-operatório. Foram analisadas as aderências macroscópicas, aspectos microscópicos e aplicado teste de tensão de ruptura. RESULTADOS: Todos os animais apresentaram aderências abdominais intraperitoneais em vários graus, sem significância estatística. Não houve diferença entre os grupos na avaliação dos testes de tensão de ruptura. Na análise microscópica o grupo A30 teve menor reação inflamatória e formação de granulomas, e menor reação do tipo corpo estranho quando comparado ao grupo B30, com resultados significativos. CONCLUSÕES: Não houve diferença significativa entre os grupos tanto em relação à formação de aderências intraperitoneais quanto à tensão de ruptura. O grupo B30 apresentou reação inflamatória e formação granulomatosa no local de fixação na parede significativamente maior que o grupo A30.


Subject(s)
Animals , Male , Rats , Abdominal Wall/surgery , Collagen/adverse effects , Polytetrafluoroethylene/adverse effects , Surgical Mesh/adverse effects , Wound Healing/physiology , Abdominal Wall/pathology , Hernia, Ventral/surgery , Herniorrhaphy/methods , Materials Testing , Random Allocation , Rats, Wistar , Tensile Strength , Time Factors , Tissue Adhesions/etiology , Tissue Adhesions/pathology
2.
Acta cir. bras ; 27(6): 376-382, June 2012. ilus, tab
Article in English | LILACS | ID: lil-626255

ABSTRACT

PURPOSE: To study the macro and microscopic evaluation of the damage caused by clamping or section of cervical sympathetic nerve in rabbits, quantifying the collagen in the lesions. METHODS: Twenty rabbits were divided into two groups of ten, doing in group 1 (section) section of the right cervical sympathetic nerve, while in group 2 (clipping) clipping of the nerve. All rabbits were induced to death on the seventh day after surgery. The macroscopic variables were: consequences of nerve lesion, clip appearance, presence of infection and adhesions around the nerve. Microscopy used hematoxylin-eosin staining to evaluate the stages and the degree of inflammation and necrosis, and F3BA Picrosirius red staining to quantify collagen. Mann-Whitney test was used for comparisons of collagen types I and III between groups. Fisher exact test analyzed the macroscopic variables, the degree of inflammation and necrosis. RESULTS: There was no discontinuity of nerve injury in the clipping group, as well as the clip was closed in all animals. The presence of severe adhesions was significantly higher in the clipping group (p<0.05). There was no significant difference on other variables macroscopically analyzed. There was no significant difference between groups regarding the type of inflammatory process and its intensity, as well as the presence of necrosis and collagen deposition in the nerves. CONCLUSIONS: In the macroscopic evaluation, the section caused discontinuity, which did not occur in the clamping group; there was no development of local infection; the clipping of the cervical sympathetic nerve was linked to the presence of a greater number of adhesions in comparison to the section group. Microscopically, no difference existed in relation to the type and intensity of inflammation reaction between the groups; occurred predominance of chronic and severe inflammation on the specimens; the necrosis was noticed equally in both groups; there was predominance of type I collagen deposition in relation to type III in both groups.


OBJETIVO: Estudar a lesão provocada pela secção e pela clipagem no nervo simpático cervical de coelhos, avaliando-se a macroscopia, microscopia e quantificando-se o colágeno nas lesões. MÉTODOS: Foram utilizados 20 coelhos, distribuídos em dois grupos de dez, sendo nos animais do grupo 1 (secção) realizada secção do nervo simpático cervical direito, enquanto nos do grupo 2 (clipagem) realizada a clipagem desse nervo. Todos os coelhos foram induzidos à morte no sétimo dia de pós-operatório. As variáveis macroscópicas avaliadas foram: presença de lesão de descontinuidade do nervo, aspecto do clipe, presença de infecção e de aderências ao redor do nervo. A microscopia com hematoxilina-eosina foi feita para avaliar as fases, o grau do processo inflamatório e a presença de necrose; a coloração de Picrosirius red F3BA quantificou o colágeno. Utilizou-se o teste de Mann-Whitney nas comparações dos colágenos tipo I e tipo III entre os grupos. As variáveis macroscópicas, o grau do processo inflamatório e presença de necrose foram analisadas pelo teste de Fisher. RESULTADOS: Não houve lesão de descontinuidade do nervo no grupo clipagem, assim como o clipe encontrou-se fechado em todos os animais desse grupo. A presença de aderências intensas foi significativamente maior no grupo clipagem (p<0,05). Não houve diferença significativa quanto às demais variáveis analisadas macroscopicamente. Não houve diferença significativa entre os grupos quanto ao tipo de processo inflamatório e sua intensidade, assim como quanto à presença de necrose e ao depósito de colágeno nos nervos. CONCLUSÕES: Na avaliação macroscópica, a secção causou lesão de descontinuidade, o que não ocorreu na clipagem; não houve desenvolvimento de infecção local; a clipagem do nervo simpático cervical foi associada à presença de maior quantidade de aderências em relação à secção. Na avaliação microscópica reconheceu-se não haver diferença no tipo e na intensidade do processo inflamatório entre os grupos; ocorreu predomínio de processo inflamatório crônico e acentuado; as necroses ocorreram igualmente em ambos os grupos; houve predomínio de depósito de colágeno tipo I em relação ao tipo III em ambos os grupos.


Subject(s)
Animals , Male , Rabbits , Sympathectomy/adverse effects , Sympathetic Nervous System/injuries , Constriction , Collagen/analysis , Eosine Yellowish-(YS) , Hematoxylin , Inflammation/pathology , Necrosis , Staining and Labeling , Sympathetic Nervous System/pathology , Sympathetic Nervous System/surgery , Tissue Adhesions/pathology
SELECTION OF CITATIONS
SEARCH DETAIL